Controlled release of testosterone and estradiol-17 β from biodegradable cylinders

រកមើល / បើក Open
Request this document
កាលបរិច្ឆេទ
1994Page views
123ទិន្នន័យមេតា
មើលកំណត់ត្រាលម្អិតនៃធាតុCited times in Scopus
Share
អរូបី
A controlled release device for the hormones, testosterone and estradiol-17 β, was developed by coating a melt extruded hormone/poly (ϵ-caprolactone) cylinder with pure polylactide. Since testosterone and estradiol-17β have much higher permeabilities in poly (ϵ-caprolactone) than in polylactide, they primarily permeate through the open ends of the cylinder, with little release through the polylactide wall. By changing the cylinder length, the release rate and duration could be adjusted. The release followed Pick's diffusion equation for a drug loading below its solubility in poly (ϵ-caprolactone) or Higuchi's equation for a drug loading above the solubility. The diffusion coefficients of testosterone and estradiol-17β in poly (ϵ-caprolactone) were estimated as \((8.31 \pm 3.12) \times 10^{−18}\) and \((0.728 \pm 0.250) \times 10^{-18} cm^{2}/s\), respectively.
Suggested Citation
Zhang, X., Wyss, U. P., Pichora, D., Goosen, M. F. A., Gonzal, A., & Marte, C. L. (1994). Controlled release of testosterone and estradiol-17 β from biodegradable cylinders. Journal of Controlled Release , 29(1-2), 157-161. https://doi.org/10.1016/0168-3659(94)90131-7